- To improve the quality of utilisation performance measures as required for the Investor Confidence Rating
- To inform Company decision making
We have a set of around 700 at-place counter devices (sensors) located across the country-mostly. It allows a representative sample of the five main types to be reported upon: Cat-1, Cat-2, Cat-3, Cat-4, Cat-5.
Figure 1: Yearly counts: the average (mean) and 95% confidence interval estimation over time
siteClass | Fyear | siteNum | Mean | Upper | Lower |
---|---|---|---|---|---|
Cat-1 | 2013/14 | 74 | 2697 | 3514 | 1880 |
Cat-1 | 2014/15 | 74 | 2943 | 3939 | 1947 |
Cat-1 | 2015/16 | 74 | 3370 | 4443 | 2297 |
Cat-1 | 2016/17 | 74 | 3458 | 4508 | 2408 |
Cat-1 | 2017/18 | 74 | 3179 | 4267 | 2092 |
Figure 2: Yearly counts: the average (mean) and 95% confidence interval estimation over time
siteClass | Fyear | siteNum | Mean | Upper | Lower |
---|---|---|---|---|---|
Cat-2 | 2013/14 | 5 | 7548 | 15619 | 0 |
Cat-2 | 2014/15 | 5 | 7688 | 15590 | 0 |
Cat-2 | 2015/16 | 5 | 7005 | 14776 | 0 |
Cat-2 | 2016/17 | 5 | 6865 | 14368 | 0 |
Cat-2 | 2017/18 | 5 | 7935 | 14804 | 1066 |
Figure 3: Yearly counts: the average (mean) and 95% confidence interval estimation over time
siteClass | Fyear | siteNum | Mean | Upper | Lower |
---|---|---|---|---|---|
Cat-3 | 2013/14 | 7 | 13402 | 26026 | 778 |
Cat-3 | 2014/15 | 7 | 12366 | 18498 | 6235 |
Cat-3 | 2015/16 | 7 | 11020 | 13331 | 8710 |
Cat-3 | 2016/17 | 7 | 14593 | 23702 | 5484 |
Cat-3 | 2017/18 | 7 | 18109 | 38186 | 0 |
Figure 4: Yearly counts: the average (mean) and 95% confidence interval estimation over time
siteClass | Fyear | siteNum | Mean | Upper | Lower |
---|---|---|---|---|---|
Cat-4 | 2013/14 | 12 | 23204 | 39573 | 6835 |
Cat-4 | 2014/15 | 12 | 25887 | 43126 | 8649 |
Cat-4 | 2015/16 | 12 | 29847 | 49441 | 10252 |
Cat-4 | 2016/17 | 12 | 32649 | 54260 | 11039 |
Cat-4 | 2017/18 | 12 | 35343 | 58180 | 12505 |
Figure 5: Yearly counts: the average (mean) and 95% confidence interval estimation over time
siteClass | Fyear | siteNum | Mean | Upper | Lower |
---|---|---|---|---|---|
Cat-5 | 2013/14 | 13 | 47154 | 89247 | 5061 |
Cat-5 | 2014/15 | 13 | 41591 | 71151 | 12031 |
Cat-5 | 2015/16 | 13 | 52346 | 98881 | 5810 |
Cat-5 | 2016/17 | 13 | 55922 | 96134 | 15710 |
Cat-5 | 2017/18 | 13 | 53948 | 88949 | 18946 |
This report uses uncalibrated counter data; i.e. the number of times the counter sensor has been triggered by a person. Uncalibrated counter data must not be used to indicate the number huamns to a place.
Report created by: Dong Wang
Requests: File an Assyst request to get more detailed information.
Help improve this report: This Asset Utilisation Report is a work-in-progress, and we welcome your feedback.
Please forward your comments to dongwangchch@gmail.com subject: Counters